Fujitsu Siemens Computers S60 User Manual

Page 25

Advertising
background image

U41221-J-Z156-1-74

17

Operating and Indicator Elements

The Front

Optical Waveguide

Color

Meaning

Power supply status

none

No mains voltage present.

green

POWER OK
Equipment switched ON, all installed
power supply units OK.

yellow

POWER WARNING
One power supply unit has failed.

orange

STANDBY
Equipment switched OFF, mains voltage
present.

Cooling status

V

CAUTION!

The PRIMERGY S60
storage subsystem
(without Remote Service
Board) switches OFF at
an interior temperature of
55°C (see section
“Cooling status LED lights
orange” on page 73)
.

green

Cooling OK
All installed fans and the interior temper-
ature are OK.

yellow

Fan warning
One fan has failed.
The temperature is OK.

orange

Cooling fault
All the fans have failed or the interior
temperature exceeds the permissible
values.

Server management
status (global SES
indicator)

none

No status indication

orange

Identification indication
(can be activated manually from
ServerView).

For troubleshooting see section “Server
Management Status LED lights perma-
nently” on page 74.

Table 1: Meaning of the Operating Status LEDs Indication