Adding a second ffx-raid controller module, 4 adding a second ffx-raid controller module – Fujitsu Siemens Computers S60 User Manual

Page 62

Advertising
background image

54

U41221-J-Z156-1-74

The FFx-RAID Controller Module

Plug-in Board Modules

Figure 22: Removing the Module

Ê

Carefully pull out the FFx-RAID controller module from the slot. Grasp the
module on the knurled screw and on the bracket so that it does not tilt.

Installing occurs in reverse order:

Ê

Make sure that the FFx-RAID controller module engages correctly in the
plug connection on the HDD backplane.

8.1.4

Adding a Second FFx-RAID Controller Module

I

The addition of a second FFx-RAID controller module may be carried-out
when upgrading the simplex configuration to a dual-active configuration.
The action cannot be accomplished during normal operation.

In a dual-active configuration, the two FFx-RAID controller modules must
accept each other as partners. This requires both modules to have the same
FW status and the same cache configuration.

Ê

Check (with SAM software) whether the FW status of the existing FFx-RAID
controller module matches that of the new FFx-RAID controller module.

Ê

If the FW statuses do no match, use the SAM software to load the firmware
with the status of the new FFx-RAID controller module onto the existing
FFx-RAID controller module.