Storage subsystem switches off, Hdd ready indicator does not light up, 4 storage subsystem switches off – Fujitsu Siemens Computers S60 User Manual

Page 83: 6 hdd ready indicator does not light up

Advertising
background image

U41221-J-Z156-1-74

75

Troubleshooting

Problem Solutions and Tips

11.1.4 Storage Subsystem Switches OFF

Temperature too high

The actually internal temperature (°C) of the storage subsystem can be
monitored from the server management via SES. If the temperature is higher as
42°C additionally an OverTemperature Flag will be set (which can be monitored
also via SES) and the cooling status LED on the front lights orange (see also
section “Cooling status LED lights orange” on page 73). Additionally the FFx-
RAID controller switches in the degraded mode.

If the internal temperature achieve 55°C the storage subsystem switches OFF.

Ê

Wait until the storage subsystem has cooled down.

11.1.5 System will not boot after Installation of New

HDD Modules

I

HDD modules should be inserted only while the system is in operation.

Configuration incorrect (FFx-RAID controller)

Ê

Call up the configuration menu and check the hard disk drives settings
(device configuration) and the additional settings (advanced configuration
options).

11.1.6 HDD READY Indicator does not light up

Ê

Check whether the HDD module has been correctly installed and locked
(see section “Installing/Removing HDD/Dummy Module” on page 38).

HDD module or HDD backplane is defective

Ê

Replace the HDD module. If the HDD READY indicator is still off, the
HDD backplane is defective. Contact the Service organization.