U41221-J-Z156-1-74

The FFx-RAID Controller Module

Plug-in Board Modules

Description of the LED indicators

LED

Description

7

CACHE

(yellow)

8

DAC

STATUS

(green)

9

DAC

POWER

ALARM

(red)

OFF

ON

OFF

Normal operation, module ready and partner
OK

I

This signal is activated only if two
FFx-RAID controller modules are
used; only the non-defective module
can indicate that the other one has
failed.

OFF

flashing

0.5 sec.

OFF

Normal operation, FFx-RAID controller
module not ready and partner OK.

OFF

flashing

1 sec.

OFF

Normal operation, FFx-RAID controller
module ready and partner failed

I

This signal is activated only if two
FFx-RAID controller modules are
used; only the non-defective module
can indicate that the other one has
failed.

OFF

OFF

ON

Alarm:
FFx-RAID controller not powered (5 VDC;
3.3 VDC)

OFF

OFF

flashing

0.5 sec.

Alarm:
FFx-RAID controller 5 VDC failed

OFF

OFF

flashing

1 sec.

Alarm:
FFx-RAID controller 3,3 VDC failed

ON

OFF

OFF

Cache dirty:
Data in cache and on the hard disk drives
are not identical (cache active)

flashing

0.5 sec.

OFF

OFF

Conservative Cache activated (DIP switch
K1 see “DIP Switches” on page 51)

flashing

0.5 sec.

flashing

0.5 sec.

flashing

0.5 sec.

Diagnosis Mode activated (DIP switch J1
see “DIP Switches” on page 51)

Table 8: FFx-RAID Controller Module: Status Indicators