Server management status, Server management status led lights permanently, 1 server management status led lights permanently – Fujitsu Siemens Computers S60 User Manual

Page 82: 3 server management status

Advertising
background image

74

U41221-J-Z156-1-74

Problem Solutions and Tips

Troubleshooting

All the fans have failed

Ê

Immediately shut down the system to prevent overheating damage in the
device.

Ê

Replace the fan module (see section “Installing/Removing the Fan Module”
on page 34).

V

CAUTION!

It is imperative when replacing the fan module during operation that
you take no longer than 30 seconds, since otherwise the temperature
in the storage subsystem exceeds the permissible limit values.

11.1.3 Server Management Status

In order to guarantee the server management for the PRIMERGY S60 storage
subsystem over SES (SCSI Enclosure Service), at least one of the two first HDD
modules (HDD1 and HDD2, see also section “Identification Marks and Loop
Addresses” on page 43)
must be installed.

This indication can be activated manually from the ServerView. Evaluation is
performed with a later version of the storage subsystem.

11.1.3.1 Server Management Status LED lights permanently

Identification indication (can be activated manually from ServerView)

The following disturbances can have occurred:

A power supply unit has failed

Short interruption of the power supply

An out-of-limit temperature condition exists

Controller partner has failed

SES monitoring has failed

Ê

Recover the disturbance as described in this section. You find further infor-
mation in the GAM software documentation.

Advertising