Mounting the rack model, 4 mounting the rack model – Fujitsu Siemens Computers S60 User Manual

Page 71

Advertising
background image

U41221-J-Z156-1-74

63

Installation

Mounting the Rack Model

10.4

Mounting the Rack Model

V

CAUTION!

Please take note of the safety information and the notes on mounting in
the rack in the chapter “Important Notes” on page 7.

At least two people are needed to position the storage subsystem in the
rack.

The rack may tip over if more than one heavy unit (e.g. PRIMERGY
K400) is removed.

For mounting the subsystem in the DataCenter Rack at first a support bracket
must be mounted on the rear left support upright of the DataCenter Rack. This
support bracket is used for the rear fixing of the left slide rail and must be
mounted level with the lower edge of the subsystem. Cage nuts and/or spring
nuts also must be inserted in the support uprights. The cage nuts are used for
fixing the support bracket and the subsystem, the spring nuts for fixing the slide
rails.

Ê

Take the installation instruction in the Technical Manual for the corre-
sponding rack model for aid.

Ê

Using the mounting aid (stencil) mark the position of the attachment points
of the storage subsystem on the support uprights (three height units).

Refer to the information on the mounting aid.

Ê

Mark the mounting points of the subsystem (knurled screws on the front) on
the front support upright. Also mark the fastening points of the slide rails on
the inside grooves of the support uprights facing backwards. The bottom
edge of the fastening flange must be flush with the top housing cover of any
device already mounted.

Ê

Place the cage nuts and/or the spring nuts in the groove of the support
uprights and/or of the support bracket at the marked attachment points. If
necessary, adjust the position of the nuts in the groove until they lock into
the correct position.

Ê

If required, you can mount one additional cable clip for vertical cable routing.

Advertising