Switches, 2 switches – Fujitsu Siemens Computers S60 User Manual

Page 58

Advertising
background image

50

U41221-J-Z156-1-74

The FFx-RAID Controller Module

Plug-in Board Modules

8.1.2

Switches

The RS232 Switch

This switch (figure 20 on page 51) enables the RS232-FFx receiver to be
switched between an external (default) and an internal (service processor on
the Remote Service Board) means of control.

LED

Description

VT100/DEBUG STATUS

(3b yellow/green)

green

yellow

flashing between green

and yellow

approx. 0.3 sec.

Voltage OK, FFx-RAID controller ready

OFF

ON

RS232 switch* on position “1” (ext) and “debug
mode” not activated

OFF

flashing

2 sec.

RS232 switch* on position “1” (ext) and “debug
mode” activated

ON

OFF

RS232 switch* on position “2” (RSB) and “debug
mode” not activated

flashing

0.5 sec.

OFF

RS232 switch* on position “2” (RSB) and “debug
mode” activated

* The switches will be described in the section “Switches”.

Table 11: RS232 and FFx Status Indicators-

Pos. Description

1

ext. RS232 (default)
The external controlling means will be attached via the VT100/DEBUG
connector (see figure 19 on page 47).

2

RSB
Internal controlling means via the service processor on the optional
Remote Service Board.

I

When the PRIMERGY S60 storage subsystem operates without

the optional Remote Service Board the switch must be set on
position “1”.

Table 12: RS232 switch settings