Installation, Hearth requirements, Floor mounted fireplaces raised fireplaces – FireplaceXtrordinair 36 DV EFIII User Manual

Page 10

Advertising
background image

1 0

Installation

(for qualified installers only)

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Hearth Requirements

The hearth must tuck

underneath this ledge.

16” Min.

36" Min. for arch face

38-1/4" Min. for

rectangular face

Cement Board

Tile, Marble, Brick, or other

Non-Combustible

Decorative Trim

(may be combustible)

Min. 3/4”

Max. 15/16”

Floor Mounted

Fireplaces

Raised

Fireplaces

When the base of the

fireplace is raised a

minimum of 3” off of the

floor surface, no hearth is

required.

Fireplace Stand

Make sure to accomodate the floor covering (carpet,

linoleum, flooring, etc.) when determining the height of

the fireplace stand (i.e. the thicker the carpet, the taller

the fireplace stand).

Base of Fireplace

Surface of Floor (carpet, etc.)

Face

3/8" Thick Tile

1/2" Cement Board

1"

Base of Fireplace

Fireplace

SIDE VIEW

Hearth Requirement:

Min. 3/4” of non-combustible material (tile

with cement board, marble, etc.)

Advertising