Installation, Electrical connection – FireplaceXtrordinair 36 DV EFIII User Manual

Page 26

Advertising
background image

2 6

Installation

(for qualified installers only)

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Electrical Connection

!

Make sure the household breaker is shut off prior to working on any electrical lines.

!

The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)

The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

1

Follow the directions below to connect power to the fireplace.

a

b

Insert the sheathed cable from the power source through
this cable clamp. Once the wires are attached, tighten
the clamp to secure the cable.

Replace
the cover
removed
in step "a".

Attach the common (white), ground (exposed or green) wires, and hot
(black) wires from the power source to the electrical connector (included
with the fireplace). Then attach the connector to the fireplace.

c

d

Standard
Screwdriver

Remove the cover from the
fireplace junction box.

1/4" Nutdriver

Electrical
Connector

WARNING: Make sure power is
off from the power lead before
conducting any wiring.

NOTE: If using the power heat duct, you may wish

to route the wiring for it at this point. See the
instructions under "Optional Equipment".

Advertising