Installation, Facing and hearth examples (continued), Side view three-dimensional view – FireplaceXtrordinair 36 DV EFIII User Manual

Page 15

Advertising
background image

Installation

(for qualified installers only)

1 5

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Facing and Hearth Examples (continued)

36 DV Fireplace

Face

3/8" Thick
Tile

1/2" Cement
Board

Wood Sub
Floor

1"

1/2" Cement Board & 3/8" thick tile
(tucked behind the face)

Side View

Three-Dimensional View

Face

Side of
Fireplace

Note how the
tile facing fits
behind the
face on the
side and top.

When hearth installation is
correctly completed, there will
be a 1/2" air space below the
access door on the face. Do
not block this air space (it is
required for access door
opening and proper air flow).

3/8" Tile

1/2" Cement
Board

WARNING:

Base of Fireplace

Base of
Fireplace

There will be a 1/16"
clearance between the finish
face and the top of the tile on
the hearth.

Wood Sub Floor

Do not install cement board underneath the fireplace. To do so
would leave a large gap underneath the finish faceplate sides.

NOTE:

Access
Door

Advertising