Installation – FireplaceXtrordinair 36 DV EFIII User Manual

Page 22

Advertising
background image

2 2

Installation

(for qualified installers only)

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Vertical Terminations with Two or Three 90° Elbows Using 6-5/8” Dia. Vent

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10 feet

(min.)

15 feet

20 feet

25 feet

30 feet

0 feet

40' (max)

5 feet

10 feet

15 feet

0 feet

5 feet

10 feet

15 feet

25'(max)

15 feet

20 feet

25 feet

30 feet

0 feet

0 feet

NOTE:
Horizontal sections require a
1/4" rise every 12" of travel.

10 feet

(min.)

40' (max)

25'(max)

Restrictor
Position # 7

NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position
may vary slightly,
especially when the
termination is near a
demarkation line.

5 feet

Restrictor
Position # 1

35 feet

35 feet

20 feet

20 feet

NOTE:

• Horizontal sections require a 1/4" rise

every 12" of travel.

• The maximum vertical height is 40'.

• The maximum horizontal length is 25'.

• One horizontal elbow is allowed. The

horizontal vent length is calculated by
adding the length before and after the
elbow (H1 + H2 = horizontal vent length).

H1

H2

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 45° or 90° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2

This is considered a

vertical elbow