Installation

(for qualified installers only)

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Termination Requirements (see the illustration below)

A

Minimum 9" clearance from any door or window

B

Minimum 12" above any grade, veranda, porch, deck or balcony

C

Minimum 12" from outside corner walls

D

Minimum 12" from inside corner walls

E

Minimum 11" clearance below unventilated soffits or roof surfaces
Minimum 18" clearance below ventilated soffits
Minimum 6" clearance from roof eaves
NOTE: Vinyl surfaces require 24"

11” Min.

6” Min.

Roof
Surface

Roof
Eaves

F

Minimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

G

Minimum 48" clearance from any adjacent building

H

Minimum 84" clearance above any grade when adjacent to public walkways or driveways
NOTE: may not be used over a walkway or driveway shared by an adjacent building

I

Minimum 48" clearance from any mechanical air supply inlet, 72" for Canada

J

Minimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

K

Minimum 36" from the area above the meter/regulator (vent outlet)

L

Minimum 36" from the meter/regulator (vent outlet)

M

Minimum 12” above the roof line (for vertical terminations)

* N o t e : In Canada the vent termination must be a minimum 2' (.6 M) tall and 2' (.6 M)

above any portion of the roof within 10' (3 M) of the vent.

N

Minimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

C

B

H

E

G

A

D

F

L

K

J

I

NOTE: Measure clearances to the nearest edge of the exhaust hood.

A

E

E

M

N

Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material

These clearances meet UMC-1994 and the CNA/CGA-B149 code standards.