background image

Installation

(for qualified installers only)

1 9

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Approved Vent Configurations

Restrictor Position

A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures
proper combustion for all vent configurations. Depending upon the vent configuration, you may be
required to adjust the restrictor position. The charts for acceptable vent configurations detail the
correct vent restrictor position.

With the face removed and
the fireplace cool, reach
above the firebox.

To Adjust the Restrictor:

To Access the Restrictor:

1

2

Determine the correct restrictor position (see the charts under
"Approved Vent Configurations" - the factory position is #1).
Lift up the adjustment plate and move it so the correct notch
falls into the slot on the adjustment bracket.

This restrictor is in position 1
(factory setting).

This restrictor is in position 7.

Adjustment
Bracket

To adjust, lift up on the
adjustment plate and
push it back.

WARNING: Use a glove to protect
your hand from burns.

Adjustment
Plate

# 8

# 7

# 2

etc.

Elbows

A maximum of
three 90° elbows or
four 45° offsets
may be used. See
the vent
configurations for
details.

NOTE: one 45°
elbow may be used
between two
horizontal
sections.

Measuring Vent
Lengths

* NOTE:
All measurements are for 6-5/8" diameter vent except for those
marked with an asterik (*), which are for 8".

Vent

Horizontal

Run

EXAMPLE:
Two 4' lengths are 7' 10-1/2"
long, but when attached to
the vent system add 7' 9" to
the vent height.

Vent

Height

Elbows add 3" to the
length of the vent system.

3"

3"

Side
View

9-5/8"
11-5/8"*

1-1/2"

1-1/2"

Vent Length
(4', 3', etc.)

Vent sections overlap
each other by 1-1/2"

46-1/4"

8-3/4" (10-3/4"*)
wide with 1-1/2" to
3-3/8" of overlap

Starter
Section

12-3/8" tall
with 1-1/2"
of overlap

Adds 8" to System Height

(Total = 9-1/4" Tall)