Installation, Mantel requirements – FireplaceXtrordinair 36 DV EFIII User Manual
Page 16
Advertising
1 6
Installation
(for qualified installers only)
Travis Industries
4040708
1 0 0 - 0 1 1 6 0
Mantel Requirements
•
The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed in this manual.
Combustible Mantels
Combustible Mantel
30" Arch face
28-1/2" Rectangular face
30-3/8” Architectural face
24
” Min. Arch Faces
22
” Min. Rect. Faces
Max.
Mantel
Depth is
8”
Non-Combustible Mantel
Non-Combustible mantels must maintain a 12"
clearance to the top of the face and be located
below the header -or- maintain a 24" clearance.
Header
46-1/8"
Non-Combustible
Mantels
Min. 12"
30" Arch face
28-1/2" Rectangular face
30-3/8" Architectural face
Max.
Mantel
Depth is
8”