Installation, Horizontal terminations using 6-5/8” diameter vent – FireplaceXtrordinair 36 DV EFIII User Manual
Page 21
Installation
(for qualified installers only)
2 1
Travis Industries
4040708
1 0 0 - 0 1 1 6 0
Horizontal Terminations using 6-5/8” Diameter Vent
Use a single 90°
elbow (NOTE:
an additional 45°
elbow may be
used on the
horizontal run).
The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.
5 feet
0 feet
0 feet
12' (max)
5 feet
0 feet
12' (max)
Use Restrictor
Position #1
10' (max)
10' (max)
5 feet
10 feet
5 feet
10 feet
0 feet
Warning:
When an elbow is used directly off
the top of the fireplace, a 2"
clearance is required above the
vent (1" below and to the sides).
3 foot length (max)
NOTE:
• Horizontal sections require a 1/4" rise every 12" of travel.
• Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.