Installation, Horizontal terminations using 6-5/8” diameter vent – FireplaceXtrordinair 36 DV EFIII User Manual

Page 21

Advertising
background image

Installation

(for qualified installers only)

2 1

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Horizontal Terminations using 6-5/8” Diameter Vent

Use a single 90°
elbow (NOTE:
an additional 45°
elbow may be
used on the
horizontal run).

The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.

5 feet

0 feet

0 feet

12' (max)

5 feet

0 feet

12' (max)

Use Restrictor

Position #1

10' (max)

10' (max)

5 feet

10 feet

5 feet

10 feet

0 feet

Warning:

When an elbow is used directly off

the top of the fireplace, a 2"

clearance is required above the

vent (1" below and to the sides).

3 foot length (max)

NOTE:
• Horizontal sections require a 1/4" rise every 12" of travel.
• Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.