Installation, Horizontal terminations using 8” diameter vent, For qualified installers only) – FireplaceXtrordinair 36 DV EFIII User Manual

Page 23

Advertising
background image

Installation

(for qualified installers only)

2 3

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Horizontal Terminations using 8” Diameter Vent

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

0 feet

0 feet

25' (max)

5 feet

0 feet

25' (max)

Restrictor

Position #7

NOTE:

• Horizontal sections require a 1/4" rise every 12"

of travel.

• The maximum vertical height is 20'.

• The maximum horizontal length is 25'.

• One horizontal elbow (45° or 90°) is allowed

when using 8" vent. The horizontal vent length is
calculated by adding the length before and after
the elbow (H1 + H2 = horizontal vent length).

20' (max)

20' (max)

5 feet

10 feet

5 feet

10 feet

0 feet

NOTE:

Restrictor positions are based upon

lab tests. The ideal restrictor position

may vary slightly.

15 feet

20 feet

10 feet

15 feet

15 feet

20 feet

10 feet

15 feet

H1

Horizontal

Elbow

Vertical

Elbow

H2

Restrictor

Position #1

6-5/8" to 8" dia. Adapter

(must be placed directly off the top of

the fireplace - Part # 925T)