FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 226

8-12
SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009
FIGURE 8-11
Removing the FAN Unit (Rear of M9000)
6. Place the removed FAN unit on an antistatic conductive mat.
7. Mount the replacement FAN unit by following the removal instructions in
and
in reverse order. Align the FAN unit with the slot guides,
insert it carefully, and secure it firmly.
Caution –
Each cabinet contains multiple FAN unit so that the cooling
specifications are satisfied even if one FAN unit fails. When replacing a FAN unit,
however, replace it as quickly as possible.
Caution –
Do not forcibly push the FAN unit when inserting it, even if it is not
moving smoothly. If the FAN unit is forcibly inserted despite the presence of any
obstruction in a slot or any problem with a connector pin, serious damage may
result.