Appendix E

XSCF Unit Replacement When XCP 1040 or 1041 Is in the Server

E-3

19. Confirm switching over between XSCFs works properly.

a. When the READY LED on XSCFU_B#1 remains lit, log in to XSCFU#0 using

a serial connection or LAN connection.

b. Confirm switching over between XSCFs using the following commands:

Confirm XSCFU#1 is now the standby, and that XSCFU#0 has become the active.

Confirm no new errors have been recorded since the check in

Step 14

.

Confirm a message "XSCFU entered active state from standby state".

Confirm a message “No failures found in System Initialization”.

20. Power on all domains.

21. Log in to XSCFU#0 and confirm all domains start up properly.

22. Check that there are no new errors.

■

In case an abnormality is encountered, take appropriate maintenance action and
contact service engineer.

■

If no abnormality is found, proceed to

Step 23

.

XSCF> switchscf -t Standby

The XSCF unit switch between the Active and Standby states.

Continue? [y|n] :y

XSCF> showhardconf

XSCF> showlogs error

XSCF> showlogs event

XSCF> showstatus

XSCF> poweron -a

XSCF> showlogs power

XSCF> showlogs error