Chapter 16
Clock Control Unit Replacement
16-7
13. Confirm that the replacement components are normal by using the
showhardconf
or showstatus command of XSCF.
Unless "*" is displayed for the replacement CLKU, it is operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note –
The showstatus command displays information on degraded components.
14. Restore the original mode switch setting on the operator panel.
Note –
When the maintenance work is completed, be sure to confirm the mode
switch setting and return the switch to Locked.
15. Close the door on the server, and lock it.