Step 8 – FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 240

9-10
SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009
FIGURE 9-9
Removing the PSU (Front of the M9000 Base Cabinet)
6. Place the removed PSU on an antistatic conductive mat.
7. Mount the replacement PSU by following the removal instructions in
and
in reverse order. Align the PSU with the slot guides, insert it
carefully, and secure it firmly.
Caution –
Each cabinet contains multiple PSUs so that the power output
specifications are satisfied even if one PSU fails. However, please refrain from the
long time operation as one PSU remains failed.
Caution –
Do not forcibly push the PSU when inserting it, even if it is not moving
smoothly. If the PSU is forcibly inserted despite the presence of any obstruction in a
slot or any problem with a connector pin, serious damage may result.
8. Go back to the terminal that is connected to XSCF, and perform the input
operation according to the instructions on the maintenance menu that is
displayed after the replacement.
2
3
1