SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009
D.4
Power Supply Conditions
and
show the power supply conditions of the UPC interface.
D.4.1
Input Circuit
Remarks: Limit the signal line chattering period to 1 ms.
D.4.2
Output Circuit
TABLE D-2
Input Power Supply Conditions
Signal name
Input conditions
*BPS/*UALM
No voltage relay contact
*BTL
Contact rating DC 12 V, 10 mA or greater (0.5 A maximum)
*ACOFF
Use of a gold-plated contact or reed relay is recommended.
TABLE D-3
Output Power Supply Conditions
Signal name
Output conditions
ER
Output voltage
VOH
DC 3.1 V (minimum)
VOL
DC 0 - 0.4 V (maximum)
Output current
IOH
-4 mA (maximum)
IOL
4 mA (maximum)
Advertising