FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 251

Advertising
background image

Chapter 10

Operator Panel Replacement

10-7

Press and hold down (for less than four seconds) the POWER switch on the
operator panel.

From a console that is connected to XSCF, execute the poweron -a command
of XSCF.

The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.

For details of the power-on operation, see

Section 4.4.2, “Powering the Server On”

on page 4-19

, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000

Servers XSCF User’s Guide.

16. Confirm that the replaced components are normal by using the showhardconf

or showstatus command of XSCF.

Unless "*" is displayed for the replacement OPNL, it is operating normally.

For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual
, or the man page.

Note –

The showstatus command displays information on degraded components.

17. Restore the original mode switch setting on the operator panel.

Note –

When the maintenance work is completed, be sure to confirm the mode

switch setting and return the switch to Locked.

18. Close the door on the server, and lock it.

Advertising