30

1

V7865 Product Manual

Jumper Settings

CMOS Password

To clear the CMOS password:

1. Turn off power to the unit.

2. Momentarily short the pins of E11 for approximately five seconds.

3. Power up the unit.

When power is reapplied to the unit, the CMOS password will be cleared.

Figure 1-2 COM1 Configuration for RS232/RS422 Select

Table 1-2 CMOS Clear - Header E11

Select

Jumper Position

Clear CMOS

In

Normal Operation

Out

Table 1-3 Boot Continuation - Header E12

Select

Jumper Position

Load Default settings and continue booting on CMOS error

In

Stop booting on CMOS error

Out

Table 1-4 COM Port (RS232/422 Select) - Header E13, E14, E15, E17

Select

E13 Position

E14 Position

E15 Position

E17 Position

RS232 In

3-5,

4-6

In

Both

Out

RS422 w/Termination

Out

1-3, 2-4

In

1-3, 2-4

RS422 w/o Termination

Out

1-3, 2-4

In

Both Out

E14

E13

E17

E15

1 3 5 1 3

E14

E13

E17

E15

1 3 5 1 3

E14

E13

E17

E15

1 3 5 1 3

RS232

RS422 w/Termination

RS422 w/o Termination

Advertising