Timers, General, Timer control status register 1 (tcsr1) – FANUC Robotics America V7865* User Manual

Page 61

Advertising
background image

61

Timers

3

Timers

General

The V7865 provides four user-programmable timers (two 16-bit and two 32-bit) which
are completely dedicated to user applications and are not required for any standard
system function. Each timer is clocked by independent generators with selectable
rates of 2MHz, 1MHz, 500kHz and 250kHz. Each timer may be independently
enabled and each is capable of generating a system interrupt on timeout.

Events can be timed by either polling the timers or enabling the interrupt capability of
the timer. A status register allows for application software to determine which timer
is the cause of any interrupt.

Timer Control Status Register 1 (TCSR1)

The timers are controlled and monitored via the Timer Control Status Register 1
(TCSR1) located at offset 0x00 from the address in BAR2. The mapping of the bits in
this register are as follows:

Field

Bits

Read or Write

Timer 1 Caused IRQ

TCSR1[0]

R/W

Timer 1 Enable

TCSR1[1]

R/W

Timer 1 IRQ Enable

TCSR1[2]

R/W

Timer 1 Clock Select

TCSR1[4..3]

R/W

Timer 2 Caused IRQ

TCSR1[8]

R/W

Timer 2 Enable

TCSR1[9]

R/W

Timer 2 IRQ Enable

TCSR1[10]

R/W

Timer 2 Clock Select

TCSR1[12..11]

R/W

Timer 3 Caused IRQ

TCSR1[16]

R/W

Timer 3 Enable

TCSR1[17]

R/W

Timer 3 IRQ Enable

TCSR1[18]

R/W

Timer 3 Clock Select

TCSR1[20..19]

R/W

Timer 4 Caused IRQ

TCSR1[24]

R/W

Timer 4 Enable

TCSR1[25]

R/W

Timer 4 IRQ Enable

TCSR1[26]

R/W

Timer 4 Clock Select

TCSR1[28..27]

R/W

Reserved

All Other Bits

R/W

All of these bits default to “0” after system reset.