background image

Chapter 12

Power Supply Unit Replacement

12-5

12.3

Mounting the Power Supply Unit

Caution –

Do not forcibly push the power supply unit into the slot. Forcibly

pushing the component in a slot may damage the component or the server.

1. Align the top of the unit with the top of the slot.

Doing so prevents the bottom of the slot from cutting the power cord at the
bottom of the unit.

2. Set the handle so that it is perpendicular to the server, and then push the

power supply unit into the slot.

3. Insert the power supply unit until it reaches the predetermined position, and

then return the handle to its original position.

4. Secure the power cord with the cord clamp.

5. Complete the replacefru command which has been executed in the XSCF

command prompt. For details, see

Section 4.4.1, “FRU Removal and

Replacement (Power supply unit/Fan unit)” on page 4-8

.

12.4

Reassembling the Server

From the XSCF Shell prompt, use the showhardconf command to verify that the
new power supply unit has been installed.

For details, see

Section 4.4.2, “Verifying the Hardware Operation (Power supply

unit/Fan unit)” on page 4-10

.

XSCF> showhardconf