4 verifying the hardware operation, Verifying the hardware operation – FUJITSU M3000 User Manual

Page 83

Advertising
background image

Chapter 4

FRU Replacement Preparation

4-15

4.5.4

Verifying the Hardware Operation

1. In response to the ok prompt, press the

E

NTER

key and enter ”

#” (default value)

and then press the ”

.” (period) key.

The domain console is switched to the XSCF console.

2. Use the showhardconf command to confirm that the new FRU has been

installed.

XSCF> showhardconf

SPARC Enterprise M3000;

+ Serial:IKK0813023; Operator_Panel_Switch:Locked;

+ Power_Supply_System:Single; SCF-ID:XSCF#0;

+ System_Power:On; System_Phase:Cabinet Power On;

Domain#0 Domain_Status:OpenBoot Execution Completed;

MBU_A Status:Normal; Ver:0101h; Serial:PP082202QX ;

+ FRU-Part-Number:CA07082-D901 A1 /541-3302-01 ;

+ CPU Status:Normal;

+ Freq:2.520 GHz; Type:32;

+ Core:4; Strand:2;

+ Memory_Size:8 GB;

MEM#0A Status:Normal;

+ Code:ce0000000000000001M3 93T2950EZA-CE6 4145-473b3c23;

+ Type:1A; Size:1 GB;

MEM#0B Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b2918;

+ Type:1A; Size:1 GB;

MEM#1A Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b28af;

+ Type:1A; Size:1 GB;

MEM#1B Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b28ab;

+ Type:1A; Size:1 GB;

MEM#2A Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b283e;

+ Type:1A; Size:1 GB;

MEM#2B Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b2829;

+ Type:1A; Size:1 GB;

MEM#3A Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b2840;

+ Type:1A; Size:1 GB;

MEM#3B Status:Normal;

+ Code:7f7ffe00000000004aEBE10RD4AJFA-5C-E 3020-223b2830;

+ Type:1A; Size:1 GB;

PCI#0 Name_Property:fibre-channel; Card_Type:Other;

PCI#1 Name_Property:fibre-channel; Card_Type:Other;

Advertising