3 mounting the fan backplane, 4 reassembling the server, Mounting the fan backplane – FUJITSU M3000 User Manual

Page 158: Reassembling the server

Advertising
background image

14-6

SPARC Enterprise M3000 Server Service Manual • February 2011

14.3

Mounting the Fan Backplane

1. Place the fan backplane on the bottom of the chassis.

Adjust the fan backplane so that it is level and it does not catch on any cables.

2. Tighten the four screws to secure the fan backplane in position.

3. Connect the signal cable for the operator panel.

The cable is on the right side of the fan backplane.

4. Mount the signal cable connector for the motherboard unit.

The cable connector is to be mounted on the rear side of the fan backplane.

14.4

Reassembling the Server

1. Mount the fan cage.

Set the button of the fan cage at the A part in

FIGURE 14-3

, and insert the fan cage

projections in the tabs (1 in

FIGURE 14-1

).

2. Mount the fan units.

For details, see

Section 13.3, “Mounting a Fan Unit” on page 13-5

.

3. Attach the air duct to the server.

For details, see

Section 5.3.2, “Attaching the Air Duct” on page 5-6

.

4. Attach the top cover.

For details, see

Section 5.2.2, “Attaching the Top Cover” on page 5-4

.

5. If the equipment rack is supplied with a Quake-Resistant Options Kit or

stabilizer, return to its original position.

For details, see

Section 5.1.2, “Sliding the Server into the Equipment Rack” on

page 5-3

.

6. Power on the server.

This procedure includes the steps of reconnecting the power cord, checking the
LED status, and turning the mode switch on the operator panel to the Locked
position. For details, see

Section 4.5.3.1, “Power-on by Using the XSCF

Command” on page 4-13

.