B.3 drive, B.3.1 hard disk drive, Drive – FUJITSU M3000 User Manual

Page 175: B.3.1, Hard disk drive

Advertising
background image

Appendix B

FRU List

B-5

The XSCF units provides the following functions by means of the XSCF firmware:

Control and monitoring of the server

Monitoring of Oracle Solaris OS, power-on self-test (POST), and OpenBoot PROM

Control and management of system administrator interfaces such as the
maintenance terminal

Control of device information

Remote message output for various events

Because the XSCF unit is mounted on the motherboard unit, it cannot be replaced
singly. For information on how to replace the motherboard unit, see

Chapter 6

.

B.3

Drive

The M3000 server consists of up to four hard disk drives and one CD-RW/DVD-RW
drive unit.

B.3.1

Hard Disk Drive

TABLE B-5

shows hard disk drive specifications.

An SAS device has two data ports. Because each data port resides in a different SAS
domain, this enables complete failover redundancy. If one path fails, communication
is performed through the other independent path.

For the replacement procedure, see

Chapter 9

.

TABLE B-5

Hard Disk Drive Specifications

Item

Description

Number of hard disk drives

4

Interface

SAS

Location

Front of the server

Active replacement/active addition

Yes (Only when it is mirroring configuration.)

Hot replacement/hot addition

Yes

Cold replacement/cold addition

Yes

Advertising