3 leds on the operator panel, Leds on the operator panel – FUJITSU M3000 User Manual

Page 29

Advertising
background image

Chapter 2

Hardware Overview

2-9

2.2.3

LEDs on the Operator Panel

TABLE 2-3

lists the server states displayed with the LEDs on the operator panel.

The three LED indicators on the operator panel indicate the following:

General system status

System error warning

System error location

Besides the states listed in

TABLE 2-3

, the operator panel also displays various states

of the server using combinations of the three LEDs.

TABLE 2-4

indicates the states that

are displayed in the course of operation from power-on to power-off of the server.

The blinking interval is 1 second (1 Hz).

In service mode, break signals can be suppressed. If the key position is switched to
Service, the server will boot into service mode the next time it reboots. Service is
selected by default at the initial power-on.

TABLE 2-3

LEDs on the Operator Panel

Icon

Name

Color

Description

POWER LED

Green

Indicates the server power status.
• On: The power to the server (a domain) is on.
• Off: The power to the server is off.
• Blinking: The server is powered off.

XSCF

XSCF
STANDBY
LED

Green

Indicates the XSCF unit status.
• On: XSCF unit is functioning normally.
• Off: Input power source is off or is just after turned on, and

XSCF unit is stopped.

• Blinking: System initialization is in progress after power

was turned on.

CHECK LED

Amber

Indicates that the server has detected an error. This is
sometimes called a locator.
• On: An error that hinders startup was detected.
• Off: Normal, or power is not being supplied.
• Blinking: Indicates that the unit is a maintenance target.