FUJITSU M3097G User Manual

Page 105

Advertising
background image

f

PF (PAGE FORMAT): Byte 1

When PF=1, it is indicated that the parameters of this command is fitted to the
SCSI>2 specification.

For this scanner, PF=1 only is supported.

Otherwise, the following error is returned:

-

Status: B©00001π (CHECK CONDITION)

-

Sense key: X©5π (ILLEGAL REQUEST)

f

SP (SAVE PAGES): Byte 1

This scanner ignores SP.

f

PARAMETER LIST LENGTH: Byte 4

Specifies the number of bytes of the mode parameter list sent in the DATA
OUT phase.

0 means that there is no data to be transferred. This is not regarded as an
error.

(2)

Mode parameter list data: DATA OUT phase (Initiator to Target)

The mode parameter list data consists of one header, 0 or more than one descriptor
block, and 0 or more than one page as one unit.

In this scanner, the descriptor block and vendor>specific area are omitted, thus the
mode parameter list data consists of one header and one page.

a. Header

The mode parameter data (header) is shown below:

Byte 0

1

2

3

(Reserved)

7

6

5

4

3

2

1

0

Block descriptor length

4 $ 80