D.1.1.7 lamp timer function, D.1.1.8 added sense code, D $ 10 – FUJITSU M3097G User Manual

Page 155

Advertising
background image

D.1.1.7

Lamp timer function

f

Functions

-

This function specifies how long the lamp will stay on.

-

This must be specified with Mode select (Page code=Xπ3Dπ).

Format of Page Code Xπ3Dπ

Parameter length = Xπ06π

Byte 0

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

f

Parameter

Byte 2

Xπ00π: The default value is 60 seconds for this scanner.
Xπ01π to XπFFπ: Specifiable between 1 to 255 seconds (XπFFπ)

Reserved

Page code = Xπ3Dπ

Parameter

Reserved

D.1.1.8

Added sense code

Following sense code are added.

The blown lamp fuse;

™Sense key=Xπ04π, Add.sense code=Xπ80π, Add.sense qualifier=Xπ03π∫.

Interlock switch is opened;

™Sense key=Xπ02π, Add.sense code=Xπ80π, Add.sense qualifier=Xπ01π∫.