7 command sequence, 1 initial sequence, Command sequence – FUJITSU M3097G User Manual

Page 122: Initial sequence

Advertising
background image

4.7

Command Sequence

This section describes the initial sequence and read sequence.

4.7.1

Initial sequence

Power ON/reset/initialize

Scanner does not respond for 3 sec

Host side

Scanner side

Receive GOOD status

Receive CHECK CONDITION

status

Request sense data

Receive UNIT ATTENTION

sense data

Verify the logical unit

INQUIRY

INQUIRY data

Respond with GOOD status

if READY

Respond with CHECK

CONDITION status if

UNIT ATTENTION

Prepare sense data

Respond with sense data

Clear sense data (Release

UNIT ATTENTION)

REQUEST SENSE

Sense data

Check status byte

Verify scanner READY

Receive GOOD status

Receive CHECK CONDITION

status

Request sense data

Receive sense data

NOT READY

HARDWARE ERROR

Check status byte

TEST UNIT READY

Status byte

REQUEST SENSE

Sense data

Respond with GOOD status

if READY

Respond with CHECK

CONDITION status if

NOT READY

Prepare sense data

Respond with sense data

End (Ready to read)

End (Ready to read)

Abnormal termination

Prepare INQUIRY data

Respond with INQUIRY data

Verify scanner READY

TEST UNIT READY

Status byte

4 $ 97