D.1.1.6 dynamic threshold, D $ 9 – FUJITSU M3097G User Manual

Page 154

Advertising
background image

D.1.1.6

Dynamic threshold

f

The change was made to the bytes in the set window parameter as follows:

-

Byte 3E

f

M3096G:

Xπ00π: Default; Simplified DTC, if IPC option is selected.
Xπ01π to XπFFπ Reserved

f

M3097G: DTC SELECTION BYTE

Reserved

b7

b6

b5

b4

b3

b2

b1

b0

Example: Xπ00π is ™Default; Simplified DTC, if IPC II option is selected∫.

DTC SELECTION
0 0: Default; Simplified DTC, if IPC II optioned.
0 1: Dynamic threshold
1 0: Simplified DTC, if IPC II optioned.
1 1: Reserved

Byte 3E

Reserved

-

Byte 2F

f

M3096G: Reserved

f

M3097G: The definitions of the byte are the same as those of M3097G

control register #3. For further details, refer to OEM
Manual 50FH5037E.
Restrictions: This byte is effective only when byte 3E is Xπ40π.

-

Byte 30

f

M3096G: Reserved

f

M3097G: The definitions of the byte are the same as those of M3097E

control register #4. For further details, refer to OEM
Manual 50FH5037E.
Restrictions: This byte is effective only when byte 3E is Xπ40π.

f

How to specify the parameter

-

When Simplified DTC is used:

Specified as ™Byte 17 (threshold)=Xπ00π, Byte 3E (DTC
SELECTION)=Xπ00π or Xπ80π.

-

When Dynamic threshold is used:

Specify as ™Byte 17=Xπ00π, Byte 3E=Xπ40π, Byte 2F/30∫.

D $ 9

Advertising