f

Status:

B©00001π (CHECK CONDITION)

f

Sense key: X©5π (ILLEGAL REQUEST)

(b) Upper left X, Y (ULX, ULY) : Bytes 6 to 9, A to D

Specified here are the X and Y coordinates of the upper>left corner of the
subwindow. The coordinates are expressed in units of 1/1200 inches relative
to the upper>left corner of the maximum scan area.

(c) Width, length (W, L) : Bytes E to 11, 12 to 15

Specified here are the width and length of the subwindow, in units of 1/1200
inches.

Notes:

1. If the area specified for any subwindow does not fit in the area of the main

window, the portion of the area outside the main window area is ignored.
Only the portion where the main and subwindow overlap (shown hatched) is
processed.

Main Window

Sub window

Sub Window

2. If subwindows in a main window overlap with each other as a result of the

values ULX, ULY, W and L specified here, this scanner returns the
following error information:

f

Status:

B©00001π (CHECK CONDITION)

f

Sense key: X©5π (ILLEGAL REQUEST)

Example:

¨ Overlapped portion

Main Window

Sub
window

Sub
window

4 $ 60