FUJITSU M3097G User Manual

Page 58

Advertising
background image

j.

Command>specific information bytes: Bytes 8 to B

On this scanner, this field is not supported and is fixed to X©00000000π.

k. Additional sense code, additional sense code qualifier: Bytes C and D

A combination of these fields specifies detailed information about the error
reported in the sense key. This scanner reports the following information:

Sense

key

Additional

sense code

Additional

sense code

qualifier

Description

0

00

00

No> sense

2

00

00

Not ready

2

80

01

Interlock switch is opened

3

80

01

Jam

3

80

02

ADF cover open

3

80

03

Document chuter empty of paper

3

80

04

Detects job separation sheet
(See Appendix A.5)

4

80

01

Blown fuse for FB motor

4

80

02

Blown fuse for heater

4

80

03

Blown lamp fuse

4

80

04

Blown fuse for ADF motor

4

80

05

Mechanical alarm

4

80

06

Optical alarm

4

44

00

Abnormal internal target

4

47

00

SCSI parity error

5

20

00

Invalid command

5

24

00

Invalid field in CDB

5

25

00

Unsupported logical unit

5

26

00

Invalid field in parameter list

5

2C

02

Wrong window combination

6

00

00

UNIT ATTENTION

B

43

00

Message error

B

80

01

Image transfer error

4 $ 33