2 physical specifications, Physical specifications, Physical specifications $ 3 – FUJITSU M3097G User Manual

Page 18

Advertising
background image

2.2

Physical Specifications

Table 2.2 Physical specifications

Item

No.

Power
requirements

Voltage (VAC) 100 to 120, 220 to 240 VAC ±10%

Single

Phase

Frequency

50/60 Hz +2% -4%

Power consumption (VA)

150 or less

Temperature
(∞C)

Operating

5 to 35

Nonoperating

-20 to +60

Relative
humidity (%)

Vibration (G)

Dimensions
(mm)

Height

Width

Depth

173

Weight (kg)

1

Specification

696

497

2

25

3

4

5

Surge current (A)

30 or less

6

Momentary power failure

100% 0.5 Hz

7

Leakage current (mA)

1 or less

8

Dielectric strength

AC 1 KV or more for one minute or more
(between FG and AG lines)

AC line noise

9

Voltage 1.2 KV pulse duration 5 os

10

11

Operating

20 to 80 (no condensation)

Nonoperating

8 to 95 (no condensation)

Operating

0.2

Nonoperating

0.4

12

Indication (%) Operating

5

Nonoperating

10

13

ESD (KV)

8 or more

14

Acoustic
noise (dBA)

Operating

53 or less

(ISO DIS 9296)

Nonoperating

40 or less

(ISO DIS 9296)

15

2 $ 3

Advertising