Installation, Electrical connection – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 13

Advertising
background image

Installation

(for qualified installers only)

1 3

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Electrical Connection

!

Make sure the household breaker is shut off prior to working on any electrical lines.

!

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence
of local codes, with the National Electrical Code, or ANSI NFPA.

The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

1

Follow the directions below to connect power to the fireplace.

6-1/4"

a

b

Insert the sheathed cable from the power source through
this cable clamp. Once the wires are attached, tighten
the clamp to secure the cable.

Replace
the cover
removed
in step "a".

Attach the common (white), ground (exposed or green) wires, and hot
(black) wires from the power source to the electrical connector (included
with the fireplace). Then attach the connector to the fireplace.

c

d

Standard
Screwdriver

Remove the cover from the
fireplace junction box.

1/4" Nutdriver

Electrical Connector
(shipped in the fireplace
behind the cover plate)

WARNING: Make sure power is
off from the power lead before
conducting any wiring.

NOTE:

If using the power heat duct, you may wish to route the
wiring for it at this point. See the instructions under
"Optional Equipment".