Installation, Facing requirements – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 23

Advertising
background image

Installation

(for qualified installers only)

2 3

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it

is considered a mantel and must meet the mantel requirements listed in this manual.

Adhesive

WARNING

: Do not use adhesive to secure the cement board or facing. The high

temperatures of the fireplace may cause adhesives to emit odors. Use mastic or thin set
(or other non-combustible, non-odorous adherent) to attach the facing to the cement
board.

NOTE: Screws may be used to secure the cement board to the fireplace. Do not
penetrate the fireplace more than 3/4”

3-1/2" Min.
(both sides)

Non-combustible Facing

The fireplace requires a concrete
board (or other non-combustible)
extending from the header to the
floor and to the framing members
on both sides. Do not use
sheetrock, plywood or other
combustible.

Header

See "Face

Dimensions"

Base of

Fireplace

Keep the set-up face (shipped
on the fireplace) in place when
installing the facing.

See "Top Facing

Clearance" Below

1"

See "Face Dimensions"

Minimum Top Facing Clearance

Arch Face

14”

Architectural Face

(Arts & Crafts, Art Deco, Neo-Classic,
and French Country Faces)

12”