Optional Equipment

(for qualified installers only)

5 5

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

8

Run the free wire from the rheostat junction box to the fireplace. Follow the directions below to connect the
heat duct circuit to the fireplace.

a

b

Insert the sheathed cable from the rheostat through a

cable clamp and push the cable clamp into the knock-out

hole to secure it in place. Once the wires are attached,

tighten the clamp to secure the cable.

Replace

the cover

removed

in step "a".

Attach the common (white), ground (exposed or green) wires, and hot

(black) wires from the cable leading to the rheostat to the molex

connector. Then attach the molex connector to the fireplace.

c

d

Standard

Screwdriver

Power

Source

for

Fireplace

Remove the cover from the

fireplace junction box.

Note: you may need to loosen this cable

clamp to ease removal of the cover plate.

1/4" Nutdriver

Electrical Connector

(included with the

heat duct kit)

To optional second

power heat vent (use

the center knock-out).

Pry out and discard

this knock-out.

Standard

Screwdriver

e

MAINTENANCE INSTRUCTIONS

Once a year the grate should be removed and the blower area cleaned. Use a vacuum to clean around the
squirrel-cage blower, being careful not to damage any of the blades.

Grill

Phillips

Screwdriver

Use a vacuum cleaner to remove

any debris from the power vent

blower.

Modulating Remote Installation

Follow the directions included with the remote for installation with the exception of the receiver heat shield.
For the 44 DV EF, use the modulating remote receiver heat shield included inside the fireplace (to the left of
the gas control valve) instead of the heat shield included with the kit.