Installation

(for qualified installers only)

1 5

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Vent Installation

In addition to the requirements below, follow the requirements provided with the vent.

Vertical Termination
(part # 1291)

Use a roof flashing and storm collar
whenever passing through the roof

Vertical Vent

Requirements

Horizontal Vent

Requirements

Minimum framing
for fire stop

Min. 1" clearance from
vertical sections to
combustible surfaces.

10"

by

10"

Use the Simpson ceiling firestop (#1263) whenever
passing through a ceiling (or enclosure and at every
floor penetration.

Combustible
Framing

Use the Travis firestop (part # 93006094) when passing
through a wall. NOTE: make sure the firestop is postitioned
correctly so the 3" clearance is allowed above the vent.

3" Min.

1" Min.

1" Min.

Combustible
Surfaces

Minimum framing

for fire stop

Minimum

12" tall

Minimum

10" wide

Slide the vent sections together and turn 1/4 turn until the sections lock in
place.

Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.

High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).

If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints of
the affected sections.

Horizontal sections require a 1/4" rise every 12" of travel

Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)