Horizontal Terminations with One Vertical Elbow

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.

N O T E

: If you are installing this fireplace with a minimum of vent rise, and are experiencing intermittent pilot

outages, you may need to install a pilot shield (SKU 250-00028). Contact your dealer for information.

NOTE:

• One horizontal elbow (45° or 90°) is allowed. The

horizontal vent length is calculated by adding the length

before and after the elbow (H1 + H2 = horizontal vent

length).

• Horizontal sections require a 1/4" rise every 12" of travel.

H1

Horizontal Elbow

(45° or 90°)

Vertical Elbow

H2

5 feet

0 feet

0 feet

25' (max)

5 feet

0 feet

25' (max)

Restrictor

Position #5

20' (max)

20' (max)

5 feet

10 feet

5 feet

10 feet

0 feet

15 feet

20 feet

10 feet

15 feet

15 feet

20 feet

10 feet

15 feet

NOTE:

Restrictor positions

are based upon lab

tests. The ideal

restrictor position may

vary slightly.

Min. 18" Rise Before First Elbow

Restrictor

Position #1