Installation, Approved vent configurations, Restrictor position – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 16: Elbows, Measuring vent lengths

Advertising
background image

1 6

Installation

(for qualified installers only)

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Approved Vent Configurations

Restrictor Position

A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures proper
combustion for all vent configurations. Depending upon the vent configuration, you may be required to adjust
the restrictor position. The charts for acceptable vent configurations detail the correct vent restrictor position.

With the face removed and

the fireplace cool, reach

above the firebox.

To Adjust the Restrictor:

To Access the Restrictor:

1

2

Determine the correct restrictor position (see the charts under

"Approved Vent Configurations" - the factory position is #1).

Lift up the adjustment plate and move it so the correct notch

falls into the slot on the adjustment bracket.

This restrictor is in position 1

(factory setting).

This restrictor is in

position 6.

Adjustment
Bracket

To adjust, lift up on the

adjustment plate and push it

back.

WARNING: Use a glove to protect

your hand from burns.

Adjustment
Plate

# 7

# 2

etc.

Elbows

See the vent
configurations for
details on how
many elbows may
be used and in
what manner.

Measuring Vent
Lengths

6-1/4"

NOTE:

All measurements

are for 8" diameter

vent.

Vent

Horizontal

Run

Vent

Height

43-1/8"

10-3/4" wide with

1-3/4" to

3-3/8" of overlap

Starter

Section

12-3/8"

3-1/2"

Side

View

1-3/4"

Vent Length

(2', 3', etc.)

NOTE:

Vent sections overlap

each other by 1-3/4"

3-1/2"

8"