2 2

Installation

(for qualified installers only)

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Hearth Requirements

6-1/4"

Do not build the hearth

above this ledge.

12” Min.

53" Min.

Cement Board

(required)

Tile, Marble, Brick, or

other Non-Combustible

Decorative Trim

(may be combustible)

Min. 3/4”

Max. 15/16”

Floor Mounted

Fireplaces

Raised

Fireplaces

When raised a minimum of 3”

off of the floor surface, no

hearth is required.

Make sure to accomodate the floor covering (carpet, linoleum,

flooring, etc.) when determining the height of the fireplace stand (i.e.

the thicker the carpet, the taller the fireplace stand).

Fireplace

Stand

6-1/4"