Optional equipment – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 54

Advertising
background image

5 4

Optional Equipment

(for qualified installers only)

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

6

Follow the directions below to wire the blower box.

Remove the cover from
the blower box.

a

b

Insert sheathed cable through the cable clamp.
After the wires have been connected tighten the
clamp to secure the cable.

Secure the ground wire to the ground stud inside the
blower box by tightening the included nut over the
ground wire. Re-attach the cover removed in step
"a".

Attach the hot (black) and common (white) wires to the
leads coming from the wires (use wire nuts).

c

d

Standard
Screwdriver

Phillips
Screwdriver

Ground Wire

7

Follow the directions below to wire the rheostat. NOTE: There are two types of junction boxes, use the
appropriate junction box for your installation.

a

Force the sheathed cable through
one of the locking flaps on the
junction box (repeat for the other
cable). Some force is needed.
The flap will lock the cable in place.

Attach the cover plate
(either white or beige) with
the included screws. Slide
the knob (either white or
beige) over the rheostat
shaft.

Attach the common (white) wires
together. Attach the ground
(exposed or green) wires together.
Then attach each of the hot (black)
wires from the cables to the two
wires on the rheostat (orientation
does not matter). Carefully pack
the wires into the junction box.

c

b

From
Blower Box

To

Fireplace

Standard
Screwdriver

NOTE:Two junction
boxes are included -
use the best box for
your installation.

Advertising