Installation, Vent requirements, Altitude considerations – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 14: Clearances, Part numbers for 8” diameter vent, Straight lengths, Terminations, Elbows, Penetration, support

Advertising
background image

1 4

Installation

(for qualified installers only)

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Vent Requirements

!

The vent must maintain the required clearance to combustible materials to prevent a fire (see “Clearances”
below). Do not fill air spaces with insulation.

!

The gas appliance and vent system must be vented directly to the outside of the building, and never be
attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance
must use it's own separate vent system.

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have found that
the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

!

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your
dealer or installer if you suspect an improperly adjusted air shutter.

Clearances

Horizontal Runs

Vertical Sections

Min. 3" Clearance Above 45°
Sloping Vent after first firestop
(5-1/2" before first firestop)

Min. 1" Clearance to the
Sides & Below the Vent
(before or after the firestop)

The Travis firestop is required
(part # 93006094) when passing
through any wall.

Min. 5-1/2" Clearance
Above the Vent
(before first firestop)

Min. 3" Clearance
Above the Vent
(after first firestop)

Min. 1" Clearance to the
Sides & Below the Vent
(before or after the firestop)

Min. 75"
(from base of fireplace)

Min. 18" rise before
first elbow.

Min. 75"
(from base
of fireplace)

Use the Simpson ceiling
firestop (#1263)
whenever passing
through a ceiling (or
enclosure and at every
floor penetration.

Part Numbers for 8” Diameter Vent

Use 8” diameter Model GS Direct Vent manufactured by Simpson Dura-Vent

only

. Follow the installation

instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429. Vent
part numbers and descriptions are listed below.

Straight Lengths

1208B

6" Pipe Length, Black

1207B

9" Pipe Length, Black

1206B

12" Pipe Length, Black

1204B

24" Pipe Length, Black

1203B

36" Pipe Length, Black

1202B

48" Pipe Length, Black

1211B

11” to 14-5/8" Adjustable, Black

Terminations

1284

Horizontal Square Termination

1285

Hor. High Wind Termination

1250

Vinyl Siding Stand-off

1291

Travis Vertical Termination

Elbows

1245B

45° Elbow, Black

1290B

90° Elbow, Black

Penetration, Support

93006094 Travis Firestop
1241

Cathedral Ceiling Support Box

1288

Wall Strap

1263

Ceiling Firestop