Installation
(for qualified installers only)
Travis Industries
4050114
1 0 0 - 0 1 1 4 9
Vent Requirements
!
The vent must maintain the required clearance to combustible materials to prevent a fire (see “Clearances”
below). Do not fill air spaces with insulation.
!
The gas appliance and vent system must be vented directly to the outside of the building, and never be
attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance
must use it's own separate vent system.
Altitude Considerations
This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have found that
the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
!
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your
dealer or installer if you suspect an improperly adjusted air shutter.
Clearances
Horizontal Runs
Vertical Sections
Min. 3" Clearance Above 45°
Sloping Vent after first firestop
(5-1/2" before first firestop)
Min. 1" Clearance to the
Sides & Below the Vent
(before or after the firestop)
The Travis firestop is required
(part # 93006094) when passing
through any wall.
Min. 5-1/2" Clearance
Above the Vent
(before first firestop)
Min. 3" Clearance
Above the Vent
(after first firestop)
Min. 1" Clearance to the
Sides & Below the Vent
(before or after the firestop)
Min. 75"
(from base of fireplace)
Min. 18" rise before
first elbow.
Min. 75"
(from base
of fireplace)
Use the Simpson ceiling
firestop (#1263)
whenever passing
through a ceiling (or
enclosure and at every
floor penetration.
Part Numbers for 8” Diameter Vent
•
Use 8” diameter Model GS Direct Vent manufactured by Simpson Dura-Vent
only
. Follow the installation
instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429. Vent
part numbers and descriptions are listed below.
Straight Lengths
1208B
6" Pipe Length, Black
1207B
9" Pipe Length, Black
1206B
12" Pipe Length, Black
1204B
24" Pipe Length, Black
1203B
36" Pipe Length, Black
1202B
48" Pipe Length, Black
1211B
11” to 14-5/8" Adjustable, Black
Terminations
1284
Horizontal Square Termination
1285
Hor. High Wind Termination
1250
Vinyl Siding Stand-off
1291
Travis Vertical Termination
Elbows
1245B
45° Elbow, Black
1290B
90° Elbow, Black
Penetration, Support
93006094 Travis Firestop
1241
Cathedral Ceiling Support Box
1288
Wall Strap
1263
Ceiling Firestop