The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is shown
below.

Fireplace Xtrordinair 44DVXXL

Vented Gas Fireplace Heater

Tested to: ANSI Z21.88-2002 “Vented Gas Fireplace Heater” and UL 307b-1995 “Gas Burning Heating Appliances for
Manufactured Homes”.

VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,
the optional factory conversion kit must be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified
installer, service agency or the gas supplier.

CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done
by a licensed or qualified service person.

CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other
liquids having flammable vapors away.

This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instruc-
tions. Use only approved coaxial direct vent system to vent this appliance to the exterior. See owner’s manual for approved
brands of venting.

10850 117th Pl. N.E. Kirkland, WA 98033

Minimum Clearances to Combustibles

Faceplate to Adjacent Wall . . . . . . . . . . . . 3-1/2”

Hearth Extension in Front . . . . . . . . . . . . . . . . . . . . . . . . . . . 12”

Wood Floor Beneath Fireplace . . . . . . . . .

0”

If Fireplace raised 3” Hearth Extension in Front . . . . .

0”

Back to enclosure . . . . . . . . . . . . . . . . . . .

1”

Hearth Extension to Sides of Faceplate. . . . . . . . . . . . . . . . 3-1/2”

Top to enclosure (from stand-offs) . . . . . .

0”

Sides to enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1”

*Faceplate to 8” Mantel (no eyebrow) . . . . . . . . . . . . . . . . . 20”

* See Owner’s Manual For Additional Mantel Clearances and Options.

L.P.

N.G.

L.P. N.G.

Input Rate on “HI” (BTU/Hr) ............ 58,000

58,000

Minimum Inlet Pressure (inches W.C.)............... 11.5” 5.5”

Input Rate on “LO” (BTU/Hr)........... 44,000

44,000

Manifold Pressure on “HI” (inches W.C.) .......... 11”

3.5”

For natural gas when equipped with the following drill size orifices:
Back #44, Center #43, and Front #45

For propane when equipped with the following drill size orifices:
Back #55, Center #55, and Front #55.

This appliance is equipped for altitudes above 2,000 feet.
Electrical Rating: 115v, 1.5 Amps, 60 Hz

Manufacture

2003

Jan.

Apr.

Jul.

Oct.

Date:

2004

Feb.

May

Aug.

Nov.

2005

Mar.

Jun.

Sep.

Dec.

0361

Report No. 028-S-26b-5

Certified for USA