Maintenance, Wiring diagram, Replacement parts list – FireplaceXtrordinair 44 DV XXL EF User Manual

Page 44: For qualified service personnel only), 120 volt wiring

Advertising
background image

4 4

Maintenance

(for qualified service personnel only)

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Wiring Diagram

Caution:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.

Fireplace

Blower

Rheostat

Junction

Box

Hot

(black)

Common

(white)

Ground

(green)

Blower Snap Disk

Optional

Power

Heat Duct

Molex

Connector

Power In

Molex

Connector

Hot

(black)

Common

(white)

Ground

(green)

Hot

(black)

Common

(white)

Ground

(green)

Heat Duct

Rheostat

Hot

(black)

Common

(white)

Ground

(green)

Hot

(black)

Common

(white)

Ground

(green)

Grounded

to Blower

Power Supply

Hot

(black)

Common

(white)

Ground

(green)

Heat Duct

Blower

Blower

Junction Box

Optional Second Heat

Duct (same rheostat and

blower wiring as above)

120 Volt Wiring

Fireplace

Rheostat

Ground

(attached to fireplace)

Green

White

White

Green

Black

Black

Black

Optional Power Heat Duct

Millivolt Wiring
(for gas control valve)

Black

Orange

White

Piezo Igniter

Thermopile

Red

Thermocouple

Copper Co-Axial

Wire

Red

Optional

Thermostat

Optional Remote

Control

Spark Electrode

Pilot Hood

On/Off Switch

Brown

7

Hot (black)

Common (white)

Ground (green)

1

3

5

7

2

4

6

8

9

12

11

10

7

9

Blue

Blue

Optional Regulator

Solenoid (24 V. DC)

Red

Brown

Gas Control

Valve

(millivolt DC)

White

Black

Black

Black

Optional Snap Disk

3

6

9

Remote

Control

Molex

Connector

1

4

11

8

2

5

Replacement Parts List

Caution:

Use only Travis Industries replacement parts. Do not use substitute materials.

Advertising