Software Functional Overview


FIC A360 Service Manual

3-45

Register

Bit Number

Function Address

Name

R/W

7 6 5 4 3 2 1 0

Logic

Default Description

D0h

BAT_CHG
_CONT

R/W RES[7:5]

C
H
G
_
R
D
Y
#

RES

[3:2]

C
H
G

2

C
H
G

1

- -

CHG_RDY#
=0 : Charge ready

CHGn
=1 : The nth battery is charged

D1h

BAT_DCH
_PRI

R/W RES[7:3]

PAT
[2:0]

- 0x00

Battery discharge priority
0 : 2 1
1 : 1 2
2 : 2 1
3 : 2 1
4 : 1 2
5 : 1 2
6 : Same as 0
7 : Simultaneously discharge
(Read only :This data can be
set using PMU register)

D2h

BAT_DCH
_CONT

R/W RES[7:2]

D
C
H
G

2

D
C
H
G

1

0: Not
discharge
1:
Discharge

-

The discharge battery can be
selected one of the batteries
can be discharged.

D3h

BAT_WAR
_ABS

R/W DATA[15:0]

*1

-

0x0000

Absolute capacity battery
Warning detection point
0x0000-0xffff (mWh)

D5h

BAT_LOW
_ABS

R/W DATA[15:0]

*1

-

0x0000

Absolute capacity battery Low
detection point
0x0000-0xffff (mWh)

D7h

BAT_WAR
_REL

R/W DATA

[7:0]

-

0x10

Relative capacity battery
Warning detection point
00-C8h (0-100% step 0.5%)

D8h

BAT_LOW
_REL

R/W DATA

[7:0]

-

0x06

Relative capacity battery Low
detection point
00-C8h (0-100% step 0.5%)

D9h

*3

FULL
_DATA

R/W DATA

[7:0]

-

0xbe

Full charge cancel point
00-C8h (0-100% step 0.5%)

Dah

CC_CUR_
DATA

R DATA

[7:0] -

0x00

Battery charging current
setting
0x01-0xff (0.02-5.10A step
0.02A)
0x00 Depends on the
battery
This register is “read only”, to
change the value, use the
register in PMU registers area.

DBh To

DCh

BTP2 R/W DATA

[15:0]

-

0x0000

0x0000: Clear the trip point
0x0001-0xffff : (mWh)
When all of the battery’s
capacities lesser than this
setting value, the BTP2 is
detected if event is enabled.

Battery
control

DDh To

DFh

Reserved R/W

Don't

care

-

-

*3:

This register is not cleared if the system is in S4-S5 state.

R(/W): This is the read only register, but the written data will be able to read back till PMU

updates the data periodically, or PMU detects the status change.