2 pmu07 ec ram list, Software functional overview – FIC A360 User Manual

Page 96

Advertising
background image

Software Functional Overview


FIC A360 Service Manual

3-39

3.7.2 PMU07 EC RAM List

The micro controller PMU07 acts as a supplement for power management control. It supports
the following functions via SMBus Command

( 0x80 , 0xC0 )

Register

Bit Number

Function

Addr

ess

Name

R/W

7 6 5 4 3 2 1 0

Logic

Default Description

00h

*3

Power unit

R(/W)

DATA[15:0] *1

-

0xffff

0x0000: mWh [Fixed value]
0xffff: Unknown

02h

*3

Design
capacity

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

04h

*3

Last Full
Charge
Capacity

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

06h

*3

Battery
Technology

R(/W) DATA[15:0]

*1 - 0xffff

0x0000 : Primary
0x0001: Secondary [Fixed
value]
0xffff: Unknown.

08h

*3

Design
Voltage

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mV)
0xffff: Unknown

0Ah

*3

Design
capacity of
Warning

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

0Ch

*3

Design
capacity of
Low

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

0Eh

*3

Battery
capacity
Granularity 1

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

10h

*3

Battery
capacity
Granularity 2

R(/W) DATA[15:0]

*1 - 0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

12h

*3

Model
number

R(/W)

DATA[15:0] *1

-

0xffff

0x0000 [Not support]

14h

*3

Serial
Number

R(/W)

DATA[15:0] *1

-

0xffff

0x0000 [Not support]

16h

*3

Battery type

R(/W)

DATA[1

5:8] *1
All bits

are 0

CELL_TYP

E

[7:0]

- 0xffff

CELL_TYPE [3:0] This code
depends on battery data
format. In the future, this code
may be added.
0x00: NiMH
0x01: Li-ion
0x10: Non-rechargeable
battery (Reserved)

1

st

Battery

[ _BIF ]

18h

*3

OEM
Information

R(/W)

DAT

A

[15:8

]

*1

All

bits

are 0

Vender[7:0] - 0xffff

Vender [7:0] This code
depends on battery data
format.
And the following name should
be described in the ASL with
the same character code.
In the future, these codes will
be added.
0: “MoliEnergy”
1: “Panasonic”
2: “”(SANYO does not agree)
3: “TBCL” (Toshiba)
4: “Sony”

*1:

The register type is word.

*3:

This register is not cleared if the system is in S4-S5 state.

R(/W): This is the read only register, but the written data will be able to read back till PMU

updates the data periodically, or PMU detects the status change.