3 authorized managers, Uthorized, Anagers – GE ML1600 User Manual

Page 111

Advertising
background image

CHAPTER 6: ACCESS CONSIDERATIONS

CONFIGURING PORT SECURITY WITH ENERVISTA SOFTWARE

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

6–15

A

(activity, severity level 2) indicates the activity on the switch.

D

(debug, severity level 3) is reserved for GE Multilin internal diagnostic information

C

(critical, severity level 4) indicates that a severe switch error has occurred.

F

(fatal, severity level 5) indicates that a service has behaved unexpectedly.

6.3.3

Authorized Managers

Just as port security allows and disallows specific MAC addresses from accessing a
network, the EnerVista Secure Web Management software can allow or block specific IP
addresses or a range of IP addresses to access the switch.

Z

Access the functionality via the Configuration > Access > IP
Access
menu item.

The window above shows the authorized access list for managing the switch. Note specific
services can be authorized. Also note that individual stations or a group of stations with IP
addresses can be authorized.

Note

It is assumed that users are familiar with IP addressing schemes (e.g. Class A, B, C etc.),
subnet masking and masking issues such as how many stations are allowed for a given
subnet mask.

Advertising